Tests list for calibration services for Sound Level Meters and Analyzers

All calibration services offered by Scantek Inc are traceable to SI (International System of Units) through standards maintained by NIST or NPL-England or PTB-Germany. All calibration services include before and after data at no extra cost.
*The basic calibration service is performed either using exclusively acoustical tests or a combination of electrical and acoustical tests.
 
Calibration using combined electrical and acoustical tests

Basic calibration*

Standard calibration

Acoustical tests    
Overall acuracy test (ANSI S1.4 #/IEC 61672-3 #9)

x

x

A-weighted global acoustical response (ANSI S1.4 #6.2.1/IEC 61672-3 #11)

x

x(if needed)

Separate calibration of the microphone (if possible)  

x(if possible)

Dosimeter (ANSI S1.25 (#7.7) ): Exponent circuit and integrator: linearity test, with ER=5 (or another one available)

x

x

 
Electrical tests    

Tests according to ANSI S1.4 - 1983 (R2001)/IEC 651:1979 

   

Input Amplifier Test: Gain Step Test/Amplifier Setting (# 5.3);

   
- performed at 1 kHz

x

x

- performed at 31.5 Hz and 8 kHz    
Level Linearity Test (# 6.9 & 6.10);    
- test performed at 31.5 Hz, 1 kHz and 8 kHz  

x

- performed at 1 kHz

x

 
Weighting Network Tests : A, C, Lin/Flat Network (# 6.2.1) (for the networks present)

x (only one)

x

Overload Detector Test: A-Network (# 8.3.1)  

x

Fast And Slow Overshoot Test (# 8.4.1)    
- performed on reference range, at one level  

x

- on reference range, repeated at one or more lower levels  

x (type 1)

Fast And Slow Single Tone Bursts Test (# 8.4.1)

x

- performed on reference range, at one level  

x

- on reference range, repeated at one or more lower levels  

x (type 1)

F/S/I Test: Steady State Response (# 6.4)

x

x

Impulse Test: Single Tone Burst (# 8.4.3 part 1)    
- performed on reference range, one level  

x

- on reference range, repeated at one or more lower levels  

x (type 1)

Impulse Test: Continuous Sine Wave Bursts (# 8.4.3 part 3)    
- performed on reference range, one level  

x

- on reference range, repeated at one or more lower levels  

x (type 1)

Peak Detector Tests: Single Square Wave Burst (# 8.4.4)  

x

RMS Detector Test: Continuous Sine Wave Burst (# 8.4.2)    
- performed on reference range, one level

x

x

- on reference range, repeated at one or more lower levels  

x (type )

RMS Detector Test: Crest Factor Test (# 8.4.2)    
- performed on reference range, one level  

x

- on reference range, repeated at one or more lower levels  

x (type 1)

 
Tests according to ANSI S1.43 - 1997(R2002) / IEC804: 1985    
Level Linearity Test (# 8.3.3)  

x

Time Averaging Test (# 8.3.2)

x

x

 

Tests according to IEC 61672 - 3: 2006: these tests are an alternative for the tests performed in accordance with IEC 651 and IEC 804 (or ANSI equivalents), listed above.    
Self-noise test (#10)  

x

Frequency Weighting (#12): A  

x

Frequency Weighting (#12): C  

x

Frequency Weighting (#12): Z  

x

Frequency and Time Weighting @ 1kHz (#13)  

x

Level Linearity on the Reference Range Level (#14)  

x

- performed at 8 kHz

x

x

- performed at 31.5 Hz, 1 kHz and 8 kHz  

x

Level Linearity Includinbg the Level Range Control (#15)

x

x

Tone-Burst Response (#16)

x

x

Peak C Sound Level (#17)  

x

Overload Indication (#18)  

x

 

Tests of filters: relative attenuation    
- digital filters: relative attenuation for selected filters (IEC 1260 / ANSI S1.11)

x (one filter: 1 kHz)

x(2 upper filters)

- analog filters: relative attenuation for all filters (IEC225)

x

x

 
Calibration using acoustical tests only Basic calibration*  
Tests according to ANSI S1.4 - 1983 (R2001) / IEC 651: 1979 (Clause # ANSI)    
Overall acuracy test at 1kHz

x

 
C-weighted global response (# 6.2.1)

x

 
A-weighted global response (# 6.2.1)

x

 
Input Amplifier Test: Gain Step Test/Amplifier Setting (# 5.3); - performed at 1 kHz

x

 
Level Linearity Test (# 6.9 & 6.10); - performed at 1 kHz (reduced test)

x

 
Fast And Slow Single Tone Bursts Test (# 8.4.1), performed on reference range, at one level

x

 
F/S/I Test: Steady State Response (# 6.4)

x

 
RMS Detector Test: Continuous Sine Wave Burst (# 8.4.2)

x

 
 
Tests according to ANSI S1.43 - 1997(R2002) / IEC 804: 1985     
Level Linearity Test (# 8.3.3)

x

 

 

Tests according to IEC 61672 - 3: 2006: these tests are an alternative for the tests performed in accordance with IEC 651 and IEC 804 (or ANSI equivalents), listed above.    
Frequency Weighting (#11): A

x

 
Level Linearity on the Reference Range Level (#14) - performed at 1 kHz

x

 
Level Linearity Includinbg the Level Range Control (#15)

x

 
 
Tests of dosimeter functions according to ANSI S1.25 - 1997    
- Exponent circuit and integrator: linearity test (#7.7) tested for ER=5

x

 
- Absolute Sensitivity test ( # 7.2.1) (if Overall accuracy above cannot be performed)

x

 
 
Tests list for calibration services for Personal Dosimeters
When possible, dosimeters are tested as Sound Level Meters with additional functions, as detailed in the tables above. For other cases, we will perform the tests listed below.
 
Calibration using acoustical tests only Basic calibration*  
Tests of dosimeter functions according to ANSI S1.25 - 1997    
- Frequency response: Low frequency test (#7.2.2) tested for ER=3,4,5

x

 
- Exponent circuit and integrator: linearity test (#7.7) tested for ER=3,4,5

x

 
- Absolute Sensitivity test ( # 7.2.1)

x

 

Custom test of Dosimeter according to IEC 61252-2002

Full test of 1/1 and 1/3 Octave Band Filters according to IEC 61260 (equivalent to ANSI S1.11)

 


Scantek, Inc., 6430 #C, Dobbin Rd, Columbia, MD 21045
Phone 410-290-7726    Fax 410-290-9167

Distributors for Norsonic Instruments, RION Instruments, CESVA Acoustical Instrumentation, Extech, Castle Group, and KCF Technologies Instruments, Metra Vibration Transducers, BSWA Transducers and Systems, and DataKustik and Causal System Software

Note: Prices listed subject to change at anytime

[Home] [Search] [About Us] [Links] [Contact Us] [Directions] [Quote/Info]

[Sound Level Meters, Dosimeters, & Community Noise Analyzers] [Frequency Analyzers]
[Vibration Level Meters & Accelerometers] [Sound & Vibration Sources & Accessories]
[Microphones, Preamplifiers, Cables] [Sound Control Devices] [Software] [Airport Systems]
[Calibration Systems]

[Consulting in Acoustical & Vibration Control & Measurement] [Instrument Rental & Leasing]
[Instrument Service] [Instrument Calibration]